| DC Input (per Channel) |
60 Cell Panel |
72 Cell Panel * |
Battery |
| Supported Input Power |
250W – 400W |
300W – 450W |
48V, 50-300AH |
| Operating Input DC Voltage Range |
18V – 60V |
18V – 60V |
47V – 60V |
| Peak Power Performance Range |
30V – 60V |
30V – 60V |
48V – 60V |
| Maximum Input DC Voltage / Current |
60V / 11.5A |
60V / 11.5A |
60V / 11.5A |
| Maximum Input Power |
330W |
330W |
330W |
| Minimum Starting Voltage |
20V |
20V |
47V |
|
|
|
| AC Output |
On-Grid, A Port |
Off-Grid, H Port |
| Rated Output Power / Peak Output Power |
960W / 1250W |
960W / 1250W |
| Nominal Output Current (RMS) |
4A |
4A – 8A |
| Maximum Output Current (RMS) |
6A |
10.5A |
| Nominal Output Voltage / Range |
240V (211V – 264V) |
100V – 240V (10V – 264V) |
| Nominal Frequency / Range |
60Hz (59.3 – 60.5) Hz |
60Hz (59.5 – 60.5) Hz |
| Power Factor / Harmonic Distortion |
>0.95 (THD < 4%, 2nd Harmonic < 1%) |
| Compatible Water Heaters or Heating Elements |
1500W to 4500W, 240V Heating Elements |
|
|
|
| Efficiency |
Data |
| Peak Efficiency / Solar MPPT Tracking |
96% / 99% |
|
|
|
| Mechanical Data |
SI |
U.S. |
| Ambient Temperature Range |
-40°C to +65°C |
-40°F to +149°F |
| Internal Operating Temperature Range |
-40°C to +88°C |
-40°F to +190°F |
| Dimensions w/o mounting bracket (L x H x W) |
32cm x 24cm x 5.8cm |
12.5" x 9.5" x 2.3" |
| Weight |
6.5 kg |
14.25 lbs |
| Cooling / Enclosure |
Natural Convection, No Fan / Potted |
| DC Wire / AC Wire |
1-2 Feet DC Wires / 10 Feet AC Wires (THHN), Copper |
|
|
|
| Compliance and Features |
Data |
| Safety and EMC Compliance |
UL1741 and IEEE1547 (E113426), CSA 107.1, FCC Part 15 Class A. |
| Rapid Shutdown |
Complies with NEC 2014/2017 690.12. |
| DC Ground Fault Detector Interrupter (GFDI) |
Built-In |
| Standard Warranty |
3 Years (Extended Warranty Available) |
| Enclosure Environment Rating / Safety |
Outdoor, NEMA 6 (IP67) / Transformer Isolated Circuits |